User's Manual

Modu-Flo
®
System
6-2
42000
R
6.1.3.1 When any pressure or blowout switch is actuated,
personnel must determine the cause for the rise in pres-
sure. After the cause has been corrected, any blowout discs
which have been ruptured will need to be replaced with an
approved disc.
6.1.4 High-Pressure and Blowout Switch Options. Table
6-2 lists the pressure and blowout switch options available
for use. Listings in the option column are used to identify the
assembly selected when a Modu-Flo system is ordered. The
option used is designated by the entry in the ordering code
as shown below:
MPP - XXX - XXX - XX - XX - XX -
XX - XX - XXX - XX
Pressure Indicator Option
Table 6-2. High-Pressure and Blowout Switch Assemblies
Part Number Description Electrical Ratings Used On Option
521-001-220 Pressure Switch Kit 5 amp at 115/230 VAC Any reservoir P1
521-001-190 Blowout Assembly 15 amp at 115,230 or 480 VAC 5-pint or 5-pound P2
0.5 amp at 115 VDC cylindrical reservoir
0.25 amp at 230 VDC
521-001-200 Blowout Assembly 15 amp at 115, 230 or 480 VAC 6, 12 or 20-pint or pound P3
0.5 amp at 115 VDC cylindrical reservoir
0.25 amp at 230 VDC
521-001-210 Blowout Assembly 15 amp at 115, 230 or 480 VAC All tanks P4
0.5 amp at 115 VDC
0.25 amp at 230 VDC
509-206-100 Blowout Disc 1450 psi None All units P5
Figure 6-1. High-Pressure Switch
FACTORY SEALED
3 WIRE CABLE
16 AWG
5 FT. LG.
RED N.O.
BLACK N. C.
WHITE COM.
1/4 NPT
1/2" FEMALE
CONNECTOR
CONDUIT
CAUTION LABEL
PRESSURE SWITCH
LUBRIQUIP, INC. A Unit of IDEX
18901 Cranwood Pkwy, Cleveland Oh
(216) 581-2000 1-800-USA-
FAX 216) 581-8945
LUBRIQUIP
542-210-120
ADJUSTMENT
COVER
MOVE
TO
ACCESS
ADJ.
6.2 HIGH-PRESSURE SWITCH
ADJUSTMENT
6.2.1 General. The high-pressure switch assembly has
an adjustable range from 400 to 4700 psi (28 to 324 bar). If
the pressure setting is to be changed from the standard
factory setting of 1150 psi (79 bar) the blowout disc must
also be changed. To prevent system damage, the pressure
switch setting should not exceed 80 percent of the blowout
disc rating. Table 6-3 lists the blowout discs available and
the maximum pressure switch setting to be used.
6.2.2 High-Pressure Switch Adjustment Procedures.