User's Manual

Trabon
®
Injecto-Flo
®
II
L12121
Page 5
PISTON DISTRIBUTOR FOR OIL
GROUP 3200 0.01 – 0.16 CM³
ORDER KEY:
Manifold
Part No.
Manifold
Old Part No.
Number of
lubrication
points
Thread D1 Main line Ø B1 H1 H2 L
558333 513-000-100 2 52
558335 513-000-102 3 M10 x 1 6 13 17 10.5 65
558337 513-000-104 5 65
558334 513-000-101 2 61
558336 513-000-103 3 M14 X 1.5 8 18 20 11 74
558338 513-000-105 5 74
Thread Plug (Old Part No.) Washer (Old Part No.)
M8 x 1
558151
(435-702-261)
558153
(435-702-415)
M10 x 1
558192
(435-702-361)
558154
(435-702-416)
M14 x 1.5
564139
(513-000-200)
564140
(513-000-201)
washer
Metering Marking
tube
4
320 - X-X-X
Number of Outlets
2 - Two
3 - Three
5 - Five
Metering
0 - 0 cm
3
- outlet closed
1 - 0.01 cm
3
2 - 0.03 cm
3
3 - 0.06 cm
3
4 - 0.10 cm
3
5 - 0.16 cm
3
Inlet Thread D1
B - M10x1
C - M14x1.5
Order Example:
Distributor group: 3200
with 3 outlets key: 3
marking from the left to the right: 0.06 - 0.10 - 0.03
Order Key: 3 4 2
Inlet Thread of the Distributor Manifold (M10x1)
Order Key: B
Order Key: 320 3-342-B
Specifi cations
Operating Pressure: 10 - 45 bar
Medium: Oil
Viscosity: 32 to 2000 cSt
Temperature Range: +0
O
C to + 70
O
C
Perm. Residual Pressure: Max. 1.5 bar