Safety Instructions

Repair
34 3A6884B
4-Way Valve Replacement
Tools Required: Phillips screwdriver, 5 mm
Allen wrench, 10 mm wrench.
Remove 4-Way Valve
1. Perform Pressure Relief Procedure,
page 10 and disconnect power to the
TSP power pack.
2. Remove top half of frame and shroud.
3. Using a Phillips screwdriver, fully loosen
retainer screw. Pull plug off from the
valve.
4. Remove finger-tight nut on top of valve.
Remove coil from valve.
5. Use a 5 mm Allen wrench to remove the
four M6 screws that secure the 4-Way
Valve to the diverter block. Remove the
4-way valve. Save the M6 screws for
reuse later.