32 3A6884B
3. Attach pump housing to manifold with
four screws and flat washers. Torque
screws to 50-70 in-lbs. (5.6-7.9 N
•m).
4. Attach pump housing to reservoir with
two screws and flat washers. Torque to
20-25 ft-lbs (27.1-33.4 N•m).
5. Replace pump guard (50) with retaining
bolt (43).
2-Way, Poppet Valve
Replacement
Tools Required: Phillips screwdriver, 7/8 in.
wrench, 3/4 in. wrench.
1. Perform Pressure Relief Procedure,
page 10 and disconnect power to the
TSP power pack.
2. Remove top half of frame and shroud.
3. Completely loosen Phillips screw from
terminal. Remove the terminal.
4. Remove top 3/4 in. top retaining nut and
discard.