Repair
3A6884B 31
Pump Installation
(High flow displacement pump shown)
Pump installation includes securing the pump
and connecting to the fluid inlet and outlet.
1. Install pump tank o-ring and manifold
seals.
2. Slide pump assembly into drive housing
while ensuring the piston rod head is
properly aligned in the assembly
housing.
NOTE: Adjust pump rod length with pump rod
puller if needed.
NOTICE
Failure to properly align piston rod head into
housing during reassembly could severely
damage the TSP power pack during
operation.