Repair
30 3A6884B
Pump Replacement
Tools Required: 13 mm wrench.
Pump Removal
(High flow displacement pump shown)
Pump removal includes disassembling the
pump guard and pump bolts and removing
the pump.
1. Perform Pressure Relief Procedure,
page 10 and disconnect power to the
TSP power pack. Tilt unit 90 degrees
backwards to keep oil from running out
when pump is removed.
2. Remove the pump guard (50) and
retaining bolt (43).
3. Remove pump bolts (qty 6).
4. Slowly slide pump out of the drive
housing. Allow filter to drain into
reservoir during removal.