Troubleshooting
3A6884B 27
TSP power pack does not run at all.
Display shows CODE 16.
Motor position sensor not
working.
1. Set TSP power pack to OFF and
disconnect power to TSP power
pack.
2. Open control box by removing 8
screws that attach control assembly
to control box.
3. Disconnect motor position sensors
and inspect for damage at
connectors.
4. Reconnect sensor.
5. Turn power ON. If code continues,
replace motor.
TSP power pack does not run at all.
Display shows CODE 17.
TSP power pack plugged
into wrong voltage.
1. Set TSP power pack to OFF and
disconnect power to TSP power
pack.
2. Locate a good voltage supply to avoid
damage to electronics.
Problem Cause Solution