Safety Instructions

Display
18 3A6884B
Secondary Menu (Stored
Data)
NOTE: Secondary Menu contains the
calibration procedure plus information that
may be useful during troubleshooting or
repair.
1. To enter Secondary Menu turn power
switch on while holding Display Button.
Continue to hold Display Button until
CALIBRATE appears.
2. CALIBRATE scrolls past on the Display.
a. Press and hold button to enter
CALIBRATION mode. Refer to
Calibration Procedure page 28
for calibration instructions.
3. Short press Display Button and SERIAL
NUMBER scrolls past on the Display.
4. Short press Display Button and
SOFTWARE REVISION scrolls past on
the Display.
5. Short press Display Button and LAST
CODE scrolls past on the Display.
a. Press and hold Display Button and
CLEAR will appear for three
seconds on the Display. NO CODE
STORED will then scroll past on
the Display.
b. Short press Display Button to return
to the CALIBRATE screen.