Owner manual

15
1)
Options / model variants
Original instructions
English
7 Troubleshooting
Fault Cause Remedy
Pressure drop Air in the system Vent the system by operating
the spray gun several times at
short intervals. If necessary,
operate the cleaner for a short
time without the high-pressure
hose connected.
High pressure nozzle blocked
worn
Clean/replace the high pres-
sure nozzle
Detergent tank empty Top up detergent tank or set
detergent metering to “0”
Pressure fluctuations Pump draws in air (only pos-
sible in suction mode)
Check that the suction set is
air-tight
Lack of water Open water tap
Water inlet hose is too long or
its cross-section too small
Use specified water inlet hose
Lack of water caused by
blocked water filter
Clean the water filter in the
water connection (never work
without water filter)
Lack of water because max.
permissible suction height has
not been heeded
• See instructions
The motor does not start when the
cleaner is switched on
The plug is not inserted prop-
erly, i.e. there is no current
Check the plug, lead and
switch and if necessary have
them replaced by a trained
electrician
The mains fuse is switched off Switch on the mains fuse
When the cleaner is switched on
the motor buzzes without starting
The mains voltage is too low or
there is a phase failure.
Have the electrical connection
checked
The pump is blocked or frozen Contact the GRACO customer
service
Incorrect cross-section or
length of the extension lead
Use lead with correct cross
section or length
The motor switches off The overload protection has
been activated due to over-
heating or overloading of the
motor
Check that the mains volt-
age and the cleaner voltage
are the same. Switch off the
cleaner and allow it to cool for
at least 3 minutes
High-pressure nozzle is dirty Change the high-pressure
nozzle
No detergents drawn in Injector is dirty or suction hose
is blocked
• Clean
Detergent tank empty Top up detergent tank
The cap on the FlexoPowerJet
nozzle is not set to low pres-
sure
See chapter 4.