User's Manual

Component Identification
3A2954D 9
Fluid Connections and
Accessories
(FIG.5)
1. Install a fluid shutoff valve (T) in the heater’s
3/4 in. npt(m) fluid inlet. Do not overtighten. Connect
the fluid supply line to the valve.
To handle fluid expansion caused by heat:
Use flexible hoses between heater and gun.
Install a properly sized accumulator down-
stream from the heater.
Install a pressure relief valve (X) pre-set to
relieve pressure when it exceeds the system
maximum working pressure.
2. If feeding an airless spray gun, install a fluid
filter (L), drain valve (M), and fluid pressure regula-
tor (N) near the heater’s 3/4-14 npt(f) fluid outlet.
Then connect the fluid outlet line.
To prevent serious injury caused by component or
equipment rupture:
Never install a shutoff device between the heater
and gun as this will trap the heated fluid and not
allow for expansion.
Never use a fluid regulator as a shutoff device if it
is installed between the heater and gun
Provide a means for adequately handling fluid
expansion caused by heat.
NOTICE
The RTD sensor must always be mounted on the out-
let side of housing (67). If you plumb the outlet to the
left side, swap position of sensor (88) and plug (82).
FIG. 5: Fluid Connections and Accessories
ti20056a
T
X
N
L
M