User's Manual
Technical Data
3A2954D 27
Technical Data
The heater can be used in the following environmental conditions: indoor use, 99% maximum relative humidity, pollu-
tion degree 2, installation category II, maximum ambient temperature 135° F (57° C).
* Main supply fluctuation not to exceed 10%.
Maximum Working Pressure ...................... 7250 psi (50 MPa, 500 bar)
Voltage/Wattage/Current*...................... SeeModels on page 2.
Fluid Passage Heat Transfer Area .................
210 in.
2
(1355 cm
2
)
Fluid Passage Dimensions (3 parallel paths) ......... Height: 0.41 in.
Width: 0.32 in.
Length: 3x48in.
Fluid Passage Equivalent Diameter................. 0.72in.(18.3mm)
Thermometer Range ............................ 64-250°F (18 - 121°C)
WettedParts .................................. StainlessSteel,Anodized Aluminum, Electroless
Nickel-Plated Steel, PTFE
Temperature Operating Range .................... 84-219°F (29 - 104°C)
Weight....................................... 51lb(23.2kg)
RTD (Model 262853 only) ........................ 1000 ohm, class B, 3-wire
Connector: M8, 4-pin male