Maintenance
3A2954D 13
Maintenance
Flushing
Clogged fluid passages reduce heating efficiency, flow
rate, and pressure. Flush or clean whenever a change in
heating efficiency, flow rate, or pressure is noticed.
1. Follow Pressure Relief Procedure, page 11.
2. Ensure main power is off and heater is cool before
flushing. Use a compatible solvent, and follow flush-
ing instructions in your fluid supply and spray gun
manual. Do not turn on heater until fluid lines are
clear of solvent.
Drain the Heater
(FIG.7)
1. Follow Pressure Relief Procedure, page 11.
2. Remove heater inlet and outlet fittings or pipe plugs.
Have a container ready to catch the fluid.
To avoid fire and explosion, ensure main power is off
and heater is cool before flushing. Do not turn on
heater until fluid lines are clear of solvent.
FIG. 7: Drain the Heater
ti20057a
Outlet
Inlet