User's Manual

Operation
12 3A2954D
Setting Heater Control
(Refer to FIG.6)
This procedure applies to model 24P016 only. Heater
262853 with RTD control has no adjustments to make
on the heater, it requires use of an external temperature
controller.
1. Set the heater control knob (33) to a trial setpoint of
4or5.
2. Start the pump and circulate fluid through the sys-
tem at a very low flow rate of about 10-12 oz/min
(0.30-0.35 liter/min).
3. After the indicator light turns off: read the tempera-
ture on the thermometer (2). If it does not match the
desired temperature, adjust the setpoint.
Adjusting for Spraying
1. Adjust pump pressure and heater setpoint to the
lowest settings needed for good fluid atomization.
2. Set all system back pressure valves (S - FIG.1on
page 5) to maintain even fluid pressure at all gun
stations.
FIG. 6: Setting Heater Control
33
05549-524
2
NOTICE
Operating the heater at its highest setting of over
180°F (82°C) for long periods of time decreases the
heater life and can cause fluid to dry out which can
cause heater clogging and a poor spray pattern.