User's Manual

Setup
38 3A2894F
f. Dispense the material into the waste container
until both the base (A) and catalyst (B) material
lines have been purged and are free of air.
g. Close the calibration check assembly.
h. Clean the nozzles of the calibration check
assembly and install the JIC caps.
i. Activate on the DM.
4. Calibrate the machine.
Perform the following procedure during initial setup of
the machine, if the flow meters were replaced, or if the
machine needs to be recalibrated.
a. Engage the trigger lock.
b. Open the base (A) and catalyst (B) air motor
slider valves.
c. Set the base (A) and catalyst (B) air motor regu-
lators.
MD2 or Ultra-lite with flexible hose:
70 psi (480 kPa, 4.8 bar).
Ultra-lite with Tri-core:
85 psi (586 kPa, 5.9 bar)