User's Manual
Repair
16 3A2824B
Indicator Light
1. See Before Beginning Repair, page 14. Relieve
pressure.
2. Wait for heaters to cool.
3. See FIG. 7. Loosen two screws (12) and remove
shield (21).
4. Disconnect jumper wires (23, DD, EE) from back of
indicator light (9), then push light out through the
front face of the control bracket (17) by depressing
the prongs on the sides of the light. See FIG.10.
5. Press new light into control bracket (16) until prongs
lock in place.
6. Connect jumper wires (DD, EE) and reassemble
heater in reverse order of disassembly.
Heater Thermostat Switch
1. See Before Beginning Repair, page 14. Relieve
pressure.
2. Wait for heaters to cool.
3. Testing: See FIG. 10. With thermostat probe (JJ)
above 75°F (24°C), and below 160°F (71°C), the
continuity across the contacts should open when
turned off, and close when turned up toward 8. You
should hear the switch click open and closed.
4. See FIG. 7. Loosen two screws (12) and remove
shield (20).
5. See FIG. 11. Detach the two push on connectors
from thermostat switch (17). One is from thermal
limit sensor (19) at GG, and dual connector HH and
FF is from heater cartridge (21) and light (8).
6. Pull heater control knob (9) off of heater control
bracket (16) face.
7. Using a phillips head screwdriver, remove
screws (25) on control bracket face to release ther-
FIG.10
22
8
16
EE
DD
TI7011a
JJ
KK
FIG.11
FF
HH
GG
17
9
16
TI7012a
22
25