Electrical Connections
Requirements For All Installations
• The user must provide external over-current protec-
tion. For installations in the United States and Can-
ada, a branch circuit breaker must be used for
over-current protection. The maximum recom-
mended circuit breaker size is 15 amps.
Power Cable Connections
The heater power cable uses a 3 conductor cable and a
NEMA L6-20P twist lock connector. If another connector
is used, follow the table below for correct wiring.
This equipment must be grounded. All electrical wiring
must be done by a qualified electrician and comply with
all local codes and regulations.
NOTICE
To help prevent heater damage, avoid spilling liquids
onto electrical components.
Cable Color Code Function
Black or Brown
Line (Mains)
White or Blue
Neutral
Green or Green/Yellow
Protective
Ground/Earth