User's Manual

Appendix A - ADM Setup Screens Overview
3A2806C 33
Advanced Screen 3
This screen allows the user to control the availability of
some key system features.
Disable Dispensing From Display: Check this box
to disable dispensing from the ADM. A footswitch,
dispense valve trigger, or other external signal will
be the only way to initiate a dispense.
Disable Modifying Temp Setpoint: Check this box
to disable modifying temperature setpoints from the
Run screens. This is only applicable if temperature
control items are installed and enabled.
Disable Operator Mode Adjustments: When this
box is checked, the user will not be able to adjust
the dispense settings in Operator Mode.
Temperature Alarm Disables Dispense: When
this box is checked, the system will reject dispense
requests when any enabled heat/chiller zones are
below/above their setpoint.
Enable Operator Mode Cavitation Alarm: Check
this box to enable cavitation alarms in Operator
Mode. Clear this box to disable cavitation alarms in
Operator Mode.
Complete Dispense with Setpoint Error: When
this box is checked, the shot will continue dispens-
ing even if the system never reaches the desired
setpoint.
Enable Shot Aborted Notification: When this box
is checked, a pop-up notification will be displayed
when a shot is aborted.
2x Trigger For Dispense: When this box is
checked, the machine will require a double trigger
pull to initiate dispensing in shot or sequence mode.
Dispense from Home Position: When this box is
checked, the machine will be required to reach a
defined home position before dispensing in shot or
sequence mode.
Advanced Screen 4
This screen is for enabling the optional ADM screens,
enabling USB log downloading, and erasing USB logs.
To enable the machine to automatically stop dispensing
when a reservoir is low: place an “X” beside the “Low
Material Disables Dispense” check box. When this fea-
ture is active, the machine will not cycle unless material
is present in the monitored reservoirs.