User's Manual
Troubleshootin
g
Code
Type Description Problem
Cause Solution
Pump dose valves did
not actuate.
Visually inspect valves
to ensure they are
operating properly;
verify they have air
pressure above 85 psi
(0.6 MPa, 6.0 bar).
EF1#
Alarm Timeout
Shutdown
Pump #
Pump tried but was not
able to move to the
park position within a
specified amount of
time.
Pump is filled with
thick paint and could
not drive piston to
end of stroke. Motor
or drive is worn or
damaged.
Observe motor and
drive assembly to
verify that the motor is
generating force.
EL00 Record
System
Power On
Record of p
ower cycle
(ON).
Indicates date and
time when system was
started.
n/a
EM00 Record
System
Power Off
Record of power cycle
(OFF).
Indicate
s date and
time when
system was
turned of
f.
n/a
EMIX Advisory
Pump Off
The pumps are not
powered and are
unable to move.
Pump power was
turned off or an error
occurred.
Start pumps by
pressing pump start
key on Advanced
Display module,
or hold down the
Standby key on the
booth control for 1-2
seconds..
EQU0
Advis
ory
USB Idle USB download
process completed,
drive may be removed.
Data transfer is
completedtotheUSB
device.
Remove USB device
from ADM.
EQU1
Record
USB S
ys.
Sett
ings
Down
loaded
Sett
ings were
down
loaded to USB
driv
e.
User
installed USB
devi
ce in ADM USB
port
.
n/a
EQU2
Record
USB Sys.
Settings
Uploaded
Settings were
uploaded from USB
drive.
User installed USB
device in ADM USB
port.
n/a
16 3A2800B