Appendix D - ADM Error Codes
3A2797G 85
V1H1
Motor Control
Undervoltage
The voltage to the MCM has
dropped to a level where
performance is greatly affected
Alarm
Tripped circuit breaker Visually check circuit breaker for a tripped condition
Supply lines providing
low voltage
Check incoming voltage to ensure it is above the
minimum operating voltage
V4A6
Red Blanket
Overvoltage
High line voltage Alarm
Incoming line voltage is
too high
Measure voltage across disconnect switch. Voltage
should measure between 190 and 264 Vac.
V4B5
Blue Blanket
Overvoltage
V4A3
Red Inline
Overvoltage
V4B1
Blue Inline
Overvoltage
V4A2
Red Hose
Overvoltage
V4B4
Blue Hose
Overvoltage
V4A7
Red Chiller
Overvoltage
V4B8
Blue Chiller
Overvoltage
V4H0
Motor Control
Overvoltage
The voltage to the MCM has
reached an unsafe level and
has been shutdown in an
attempt to prevent damage
Alarm
Supply lines providing
high voltage
Check incoming voltage to ensure it is below the
maximum operating voltage
W0U0
USB Update
Failed
The ADM tried to upload a
system settings file but failed
Alarm
System Settings file is
corrupt
Replace the system settings file with a backup or new
file
System Settings file is
intended for another
system
Ensure that the first line in the settings.txt file contains
the text GMS
. If not replace the file with the proper
system update file.
WBH1
Motor
Encoder Fault
An error has been detected on
the motor position sensor
Alarm
Failing sensors If error persists the motor will need to be replaced
Loose connection
Ensure the d-sub connector to the motor is connected
and the wiring is intact
WDF1
M1 Material
Rod Shift Fail
The material rod failed to move
on a straight head
Alarm
Stuck material rod Check that material rod is able to freely move
No power to directional
valve
Make sure the directional valve has power
WKH1
High Motor
Speed
The motor has reached a
speed that should not be
reached in normal operation
and was shutdown to prevent
possible damage
Alarm
No power to directional
valve
Make sure the directional valve has power
Bad directional valve
connection
Make sure the cord to the directional valve is
connected to the correct port and the cord is not
damaged
Directional valve failure The directional valve will need to be replaced
Hydraulic power pack
failure
The hydraulic power pack will need repair
Defective encoder Replace encoder
Motor no longer coupled
to hydraulic pump
Reset coupler per specifications and retighten set
screws
Supply tube from
hydraulic pump to
manifold is loose or
broken
Retighten or replace supply tube
Broken motor shaft Replace motor
Error
Code Error Name Error Description
Error
Type Cause Solution