Appendix D - ADM Error Codes
82 3A2797G
T2AA
Red Hose
Low Fluid
Temp.
Fluid temperature for a monitor
zone is below the defined low
alarm limit
Deviation
Temperature is out of
alarm limits
Check temperature alarm limits
T2AE
Red Tank
Low Fluid
Temp.
T2AF
Red Chiller
Low Fluid
Temp.
T2BC
Blue Hose
Low Fluid
Temp.
T2BD
Blue tank Low
Fluid Temp.
Cable unplugged/loose
power
Check for loose or disconnected wires or plugs
T2BG
Blue Chiller
Low Fluid
Temp.
T3AA
Red Hose
High Fluid
Temp.
Fluid temperature for a monitor
zone is above the defined high
alarm limit
T3AE
Red Tank
High Fluid
Temp.
T3AF
Red Chiller
High Fluid
Temp.
Inline heater is not turned
on
Turn on inline heater
T3BC
Blue Hose
High Fluid
Temp.
T3BD
Blue Tank
High Fluid
Temp.
T3BG
Blue Chiller
High Fluid
Temp.
T3H1
Oil Temp.
Cutback
The hydraulic oil temperature
is approaching a level where
damage is possible so the
Motor Control Module is
limiting the output to a safe
level
Deviation
No power to fan Check cord to make sure fan has power
Debris is fan or fan grill Clear debris from fan/fan grill
Low air volume from fan
Try to stop fan by lightly pressing on the center with a
pencil eraser. If the fan slows down easily it will need
to be replaced
T3N1
Motor Temp.
Cutback
Motor temperature is
approaching a level where
damage is possible so the
motor control module is limiting
the output to a safe level
Advisory
No power to fan Check cord to make sure fan has power
Debris is fan or fan grill clear debris from fan/fan grill
Low air volume from fan
Try to stop fan by lightly pressing on the center with a
pencil eraser. If the fan slows down easily it will need
to be replaced
Ambient environmental
conditions are too hot
Move machine to an area below 120°F
Motor/pump coupler may
be rubbing on hydraulic
pump
Reset coupler per specifications and retighten set
screws
Error
Code Error Name Error Description
Error
Type Cause Solution