User's Manual
Appendix D - ADM Error Codes
3A2797G 79
L8A1
Red Tank
Sensor
Failure
A level sensor had ceased
working
Deviation Bad level sensor Replace level sensor
DR6B
Blue Tank
Sensor
Failure
L9AX
Red Tank
Leak
Detected
A tank or material line is
leaking
Alarm
Two tank refills occur
without a dispense
Check all hoses and pumps for material leaks
L9BX
Blue Tank
Leak
Detected
L9A0
Prepoly
Refresh Time
Expired
Prepoly refresh took longer to
complete than normal
Alarm
No material is sensed by
the second level sensor
within an allotted amount
of time
Check for an obstructions within the material supply
line
MBH1 Low Oil Level
The volume of oil in the tank is
below the minimum level
needed for the system to
properly operate
Alarm
Low oil level Check oil level and if low add more hydraulic fluid
Loose/bad connection
Check to ensure the hydraulic oil level sensor is
properly connected to the MCM and that the wire has
not been damaged
Bad level sensor Replace sensor
Leak in hydraulic driver
Inspect hydraulic driver end seals and early leak
detection tubing. Replace seals as necessary and
replace lost oil.
Leak in the hydraulic
reservoir, heat
exchanger
Inspect the hydraulic reservoir fittings and filter for
leaks. Repair or replace as necessary and replace
lost oil.
MBN1
Low Motor
Performance
The motor magnetism has
decreased to the point where
performance is greatly reduced
Advisory
Prolonged exposure to
heat or high voltage
If error persists and performance can no longer
satisfy the user requirements the motor will need to
be replaced
MMUX
USB Logs
Full
USB log has reached the
maximum entries
Advisory
USB logs have not been
downloaded
Download USB logs to a memory stick
Uncheck the Enable USB errors on Advanced screen
4
N1D0
Material
Dispense
Below Alarm
Material dispense is below the
defined limit
Alarm
Cogs in flow meter are
not turning
Check that flow meter is matched to nominal pump
output
N2D0
Material
Dispense
Below
Deviation
Deviation
N3D0
Material
Dispense
Above
Deviation
Material dispense is above the
defined limit
Deviation
Cable unplugged/loose
power
check for loose or disconnected wires or plugs
N4D0
Material
Dispense
Above Alarm
Alarm
Error
Code Error Name Error Description
Error
Type Cause Solution