Appendix D - ADM Error Codes
3A2797G 77
CAA2
Comm. Error
Red Hose
Communication error Alarm
Module missing power Check power supply connection
CAA3
Comm. Error
Red Inline
Module not programmed Program the module
CAA6
Comm. Error
Red Blanket
Module bad Replace module
CAA7
Comm. Error
Red Chiller
CAB1
Comm. Error
Blue Inline
CAB4
Comm. Error
Blue Hose
CAB5
Comm. Error
Blue Blanket
CAB8
Comm. Error
Blue Chiller
CAC1
Comm. Error
Motor
CAC2
Comm. Error
MCM
CAC3
Comm. Error
Red Tank
CAC4
Comm. Error
Blue Tank
CAC5
Comm. Error
Mix Head
CAC6
Comm. Error
Mix Head 2
CAC7
Comm. Error
Ratio Monitor
CACN
Comm. Error
Gateway
CACP
Comm. Error
DGM
CACR
Comm. Error
Remote
Pendant
CUCN
Gateway
Heartbeat
Error
Heartbeat Error Alarm
PLC is not maintaining
heartbeat
Ensure PLC is triggering the heartbeat
Module missing power Check power supply connection
Module not programmed Program the module
Module Bad Replace module
D1A1
Setpoint Not
Reached
The set point was not reached
and the pump was shutdown
Deviation
Material restriction too
high for requested flow
Reduce flow request
D4A1
Setpoint
Exceeded
The maximum cycles per
minute of the pump has been
exceeded
Deviation
Restriction for the pump
is not sufficient
Increase the restriction or lower the set point
D2A1
Setpoint Not
Reached
The set point was not reached Deviation
Pump cannot reach the
requested pressure
Increase restriction in the system
Pump cannot reach the
requested flow
Decrease restriction in the system
D3A1
Setpoint
Exceeded
The set point was exceeded Deviation
System underwent a
change that caused a
large drop in restriction
(such as new orifices)
Erase learned System Data, found in the setup
screens under calibration
No material in pumps
Make sure the material lines are open and have
proper feed pressure
Error
Code Error Name Error Description