User's Manual
Appendix B - ADM Setup Screens Overview
68 3A2797G
Advanced Screen 4
• Enable Diagnostic Screen: Check this box to
enable the optional ADM screens, enabling USB log
downloading, and erasing USB logs. For more infor-
mation about USB operation, see Appendix F -
USB Operation on page 89. For more information
about the optional screens, see Diagnostic screen
on page 74.
• Low Material Disables Dispense: When this box is
checked, the current dispense will terminate and
prevent additional dispenses when the supply sys-
tem indicates a low level.
• Limit Rate on Stall to Pressure: Check this box to
enable Limit Rate on Stall to Pressure. This will slow
the rate of pressure rise on a stall to pressure sys-
tem.
• Enable Range Calibration: Check this box to
enable Range Calibration. This creates a range of
shot offsets in a table based on the size of the shot.
The user must calibrate each range at the specified
flow rate. If the flow rate is changed, the table must
be recalibrated.
• Enable PrePoly Refresh: Check this box to enable
Prepoly Refresh. A Prepoly refresh will initiate a
cold start, heat the system to a specified tempera-
ture (Conditioning Screen 3), empty the prepoly
tank to the low level sensor and refill the tank. When
enabled, either the user may initiate a refresh manu-
ally or through a scheduled task.
• Night Mode, Disabled, or Standby Modes:
Automatic refills are disabled. If the material
level drops below the low level sensor, a low
level alarm is thrown.
• Shot, Operator or Sequence Modes: The sys-
tem will monitor the amount of automatic refills
requested after the last shot has been taken. If
the system sees two refills without dispensing,
the system will generate a leak detection warn-
ing and disable the system. The system must be
completely powered down to clear the error.
• Enable Leak Detection: Check this box to enable
Leak Detection. Leak detection is intended for cata-
strophic leaks only. It requires a Graco auto fill con-
trol to be enabled and working. Leak detection is not
active during dispense.
Advanced Screen 5
This screen displays software information.
Numbers shown are for reference only and may
be different on your system.