User's Manual
Appendix B - ADM Setup Screens Overview
3A2797G 65
2. Press to display the setpoint and alarm values
associated with that component.
3. Edit the setpoint and alarm values and then press
to return to Conditioning Screen 2.
NOTE: The high alarm and low alarm values must be at
least +/-9°F (5°C) than the material temperature value.
Conditioning Screen 3
This screen allows the user to configure Night Mode
operation. In Night Mode, the system will cycle on and
off periodically or turn on at a preset time. Press
and select periodic or time schemes.
When the system is in Night Mode and in an “On” cycle,
the system will circulate in low pressure. The installed
conditioning zones will be on and controlling to their
respective setpoints. When the system is in Night Mode
and in an “Off” cycle, the system will be idle. The system
will not be circulating and the conditioning zones will not
be actively controlling temperature. When in Night
Mode, supply tanks will not fill.
Periodic Night Mode Conditioning Screen
This screen allows the user to set the on and off times of
the machine in one minute intervals.