Appendix B - ADM Setup Screens Overview
64 3A2797G
Refill Timeout
The refill time-out setting may be set by the user as a
means to abort the refill in the case of a high level sen-
sor failure. When an automatic refill begins, the time-out
counter will begin to count down. If the timer expires
before the high level sensor is triggered, the refill will
abort. A refill must be manually started to enable auto
refills again.
Refill Sensor Type
The Low-Temp Sensor setting limits tank temperatures
to 150°F (66°C). And the High-Temp Sensor setting lim-
its tank temperatures to 190°F (88°C).
Conditioning Screen 1
This screen allows the user to select which temperature
conditioning components are installed in the system.
Check the box next to the component type for the appro-
priate side of the system to indicate that a component is
installed. A maximum of four components and two moni-
toring zones may be selected.
Conditioning Screen 2
This screen shows the fluid path for the temperature
conditioning components and temperature setpoints for
each component.
NOTE: If tank blanket heaters or inline heaters are
installed along with hose heat, the hose heat setting will
be limited to at or below the inline or tank heat setting.
To edit the temperature setpoint and alarms for a partic-
ular component:
1. Press then use the arrow keys to navigate to
the component you wish to edit.
NOTICE
If you are using low temperature sensors and select
the High-Temp Sensor setting and set the tempera-
ture above 150°F (66°C), damage to the level sen-
sors will occur.
NOTE: All components are shown installed for refer-
ence only. Only 4 components and two monitoring
zones can be installed at one time.