User's Manual

Appendix B - ADM Setup Screens Overview
3A2797G 59
Calibration Screen, Main
This screen shows calibration information for the system
and provides access to other calibration screens. See
Calibrate HFR on page 37 for how to use the calibration
screens to calibrate the machine.
The date next to each key represents the last time that
calibration was performed.
The “Cal. Min” and “Cal. Max” values are the system
recognized extreme ends of piston travel. See Calibra-
tion Screen, Learn Mode.
Press to go to the Calibration Screen, Learn
Mode screen.
Press to erase the motor control database in the
motor control module.
Calibration Screen, Learn Mode
This screen allows the user to calibrate piston position.
The piston can be moved to the left and right to obtain
the full range of motion. See Calibrate HFR on page 37
for how to use this screen to calibrate the machine.
Press and then to move the pump all the way
to the left.
Press and then to move the pump all the way
to the right.
Press to return to the Calibration Screen, Main.
This saves the new left and right numbers.
Previously saved left
position
Previously saved right
position
Current position