User's Manual

Appendix B - ADM Setup Screens Overview
58 3A2797G
Weight Based Example Using Shot Calibration
Table:
NOTE: The offset needs to be determined for each
range and may need to be modified if the flow rate
changes. Visit www.graco.com and search for PKE
“Shot Calibration Table Worksheet” to assist in the cal-
culations for the following procedure.
NOTE: Offset ranges are dependant on material ratio
and material specific gravity. The values shown are for
reference only.
1. Dispense five shots into separate containers for an
average range.
2. Measure the amount for each shot size and record
the data.
3. Repeat steps 1 and 2 for all twelve ranges.
4. Calculate the average for each range and record the
data.
5. Calculate the offset of each shot size and record the
data.
6. Enter the offset into the table.
7. Repeat steps 1 through 6 for more precise offsets.
Example:
Sequences Screen
This screen allows the user to edit sequence informa-
tion.
See Home Screen, Sequence Mode on page 71 for
information on how to use predefined sequences.
NOTE: Five sequences with 20 positions each are avail-
able across 10 pages.
NOTE: Sequence positions are made from shots
defined in the Shots Screen.
To edit a sequence:
1. Press then use the arrow keys to navigate to the
desired value.
2. Type the new value then press to accept the
new value.
(Shot1 + Shot2 + Shot3 + Shot4 + Shot5)
5
Target Shot Size - Average Shot Size
Step
Ref.
Shot
Number
Range: 11-15g
Target Shot Size: 13g
1,2 Shot 1 11.600
1,2 Shot 2 12.200
1,2 Shot 3 12.400
1,2 Shot 4 11.900
1,2 Shot 5 12.000
4 Average
Shot Size
12.02
5 Offset 0.98