User's Manual
Startup
3A2797G 43
Startup
1. Check that all machine connections are setup. See
Setup procedure, page 28.
2. Check level and condition of ISO lube daily, see
IsoGuard Select
™
System on page 48.
3. Verify both PRESSURE RELIEF/DISPENSE valves
(SA, SB) are set to DISPENSE .
4. If dispense valve has a trigger safety lock, engage
the trigger safety lock.
5. Open system fluid inlet valves and ball valves found
on the material tanks. As applicable, ball valves on
the material tanks include material supply, applica-
tor return, and pressure relief. Check for leaks.
6. Press to enable system. LED should be solid
green.
7. Navigate to Home Standby screen and press
to initiate auto startup.
8. Check that heat zones are on and temperatures are
on target. Check fluid pressure display. Refer to Sta-
tus Screen on page 72 for more details.
9. If dispense valve has a trigger safety lock, disen-
gage the trigger safety lock.
i. Equipment is ready to dispense.
To reduce the risk of personal injury, do not operate
HFR without all covers and shrouds in place.