User's Manual

Models
4 3A2797G
Models
System
Full Load
Peak Amps
Per Phase*
Voltage
(phase)
Primary
Heater
Watts
A (Red)
Primary
Heater
Watts
B (Blue)
Max Flow
Rate
lb/min
(kg/min)
Approximate
Output per
Cycle (A+B)
gal. (liter)
Hydraulic
Pressure
Ratio
Maximum
Fluid Working
Pressure ‡
psi (MPa, bar)
24N569 90 230V (3)
6,000
4,000
18 (8.2) 0.033 (0.125) 1.9:1
2000
(14, 138)
24N570 68 400V (3)
24N571 90 230V (3)
24 (11) 0.045 (0.170) 1.4:1
24N572 68 400V (3)
24N573 90 230V (3)
6,000 17 (7.7) 0.032 (0.121) 3.7:1
24N574 68 400V (3)
24N575 90 230V (3)
4,000 18 (8.2) 0.033 (0.125) 1.9:1
24N576 68 400V (3)
System
Material
Ratio
(A:B)
A (Red)
Pump
Size
B (Blue)
Pump
Size
A (Red)
Orifice
B (Blue)
Orifice
25’ (7.6 m)
Chemical
Hose Bundle
10’ (3 m)
Chemical
Hose Bundle
24N569
24:1 120 5 .061 .011
24J290 24J316
24N570
24N571
16:1 160 10 .057 .014
24N572
24N573
1:1 60 60 .039 .039 24N287 24N289
24N574
24N575
24:1 120 5 .085 .013 24K681
24N576
System
27.5’ (8.4 m)
Hydraulic
Hose Bundle
10’ (3 m)
Hydraulic
Hose Bundle
24N569
24V197 24J177
24N570
24N571
24N572
24N573
24N574
24N575
24N576