12.
Setup the Advanced Display Module (ADM)
When main power is turned on by turning the main
power switch (MP) to the ON position, the splash screen
will be displayed until communication and initialization is
complete.
To begin using the ADM, the machine must be on and
enabled. To verify the machine is enabled, verify the
System Status Indicator Light (CB) is illuminated green,
see F
IG
. 6 on page 20. If the System Status Indicator
Light is not green, press the ADM Power On/Off (CA)
button . The System Status Indicator Light will illu-
minate yellow if the machine is disabled.
The blue token (24M560) must be installed to enable
cold start up, temperature monitor zones, and shot times
less than one second.
If the machine is in the Disabled mode screen press
repeatedly to select standby mode.
Navigation
Press or to navigate to new screens.
Press or to navigate to new screens or
to move between fields.
Press to activate the desired field or to acti-
vate/deactivate an option.
Perform the following tasks to fully setup your system.
Enter Setup Mode by pressing the button.
a. Define shots. See Shots Screen, page 55 for
more detail.
b. Define sequences. See Sequences Screen,
page 58 for more detail.
c. Calibrate HFR, page 37. See Calibration
Screen, Main, page 59 for more detail.
d. Define pump information. See
System Screen 1, page 60 for more detail.
e. Define dispense valve and other system set-
tings. See System Screen 2, page 60 for more
detail.
f. Define labels and other system settings. See
System Screen 3, page 61 for more detail.
g. If desired, view/reset counters. See Mainte-
nance Screen, page 62 for more detail.
h. Define level sensors and refill settings. See
Supply Screen, page 63 for more detail.
i. Enable/disable temperature conditioning com-
ponents. See Conditioning Screen 1, page 64
for more detail.
j. Define temperature conditioning setpoints. See
Conditioning Screen 2, page 64 for more
detail.
k. If Night mode will be used, define Night mode
settings. See Conditioning Screen 3, page 65
for more detail.
l. Set general system settings. See Advanced
Screen 1, page 67 for more detail.
m. Set units of measure. See Advanced Screen 2,
page 67 for more detail.
n. Enable/disable system features. See Advanced
Screen 3, page 67 for more detail.
NOTICE
To ensure proper machine operation, the blue token
must remain installed in the ADM during operation.