User's Manual
Setup
3A2797G 35
together. This creates a hydraulic fluid circula-
tion loop.
e. Turn on the power pack by navigating to the
Home Screen, Standby Mode and press .
Circulate oil for 3 minutes to purge air from
hydraulic hoses.
NOTE: Pressure should not increase while air is purged
from hoses.
f. Turn off the power pack by pressing . Look
at the gauge to verify no pressure exists in the
hydraulic hoses and the AC Power Pack.
g. Remove the 7/16 in. JIC male-male adapter
connecting the hydraulic hoses.
h. Fill both open and close gun chambers with
hydraulic fluid.
i. Attach hydraulic hoses to the gun. Tighten each
fitting 1/4 turn past hand tight.
NOTE: The hydraulic hose marked with both green and
white stripe is for the open port of the gun. The hydraulic
hose marked with only a green stripe is for the close
port of the gun.
j. Attach trigger switch cable (if applicable) to gun
and HFR.
F
IG
. 18: Hydraulic Loop
NOTICE
To prevent air from entering the hydraulic hoses, do
not spill oil while disassembling the adapter connec-
tion. If spilling occurs, replace the lost fluid by man-
ually filling the hoses with hydraulic fluid.
ti14495a
F
IG
. 19: Hydraulic Connections
F
IG
. 20: Cable Connections
ti14496a
ti14494a