User's Manual
Component Identification
26 3A2797G
Adjust Rotary Switch
The rotary switch setting indicates which zone the tem-
perature control module will control in the system. The
high power module uses an 8-position rotary switch. The
low power module uses a 16-position rotary switch.
Set the rotary switch (S) to the specific selection accord-
ing to the settings listed in the following tables.
High Power Module Rotary Switch Settings
Low Power Module Rotary Switch Settings
F
IG
. 12: Rotary Switch
High Power Module Rotary Switch Location
Low Power Module Rotary Switch Location
S
S
ti12360a
ti12361a
Setting Zone
0 Not Used
1 B (Blue) Primary Heat
2 B (Blue) Hose Heat
3 A (Red) Primary Heat
4 A (Red) Hose Heat
5 through 7 Not Used
Setting Zone
0 through 4 Not Used
5 B (Blue) Tank Heater
6 A (Red) Tank Heater
7 B (Blue) Chiller
8 A (Red) Chiller
9 through F Not Used