User's Manual
Technical Data
3A2776D 85
Technical Data
XM PFP
US Metric
Mix Ratio Range 1:1-10:1 (in 0.01 increments)
Ratio Tolerance Range (before alarm) +/- 5%
Maximum Flow Rate (measured with oil) 3 gallons per minute 13.6 liters per minute
Fluid Viscosity Range
Handles mastic materials which are loaded into heated tanks
with ram-fed priming piston pumps
Air Inlet 1 in. npt(f)
Fluid Inlets Pail (Feed Pumps)
Maximum Fluid Working Pressure for A and B
Materials
6000 psi 41 MPa, 414 bar
Maximum Fluid Working Pressure for Flushing
Fluid
4500 psi 31 MPa, 310 bar
Maximum Fluid Working Pressure for Heating
Fluid
100 psi 0.7 MPa, 7 bar
Maximum Fluid Temperature 160°F 70°C
System Inlet Supplied Air Pressure Range 80-150 psi 0.5-1.0 MPa, 5.5-10.3 bar
Maximum Pump Air Pressure 100 psi 0.7 MPa, 7 bar
Maximum Tank Air Pressure 90 psi 0.6 MPa, 6 bar
Air Filtration 40 micron main filter, 5 micron control air filter
Ambient Operating Temperature Range 32 to 130°F 0 to 54°C
Ambient Storage Temperature Range 30 to 160°F -1 to 71°C
Environmental Conditions Rating Altitude up to 13,123 ft Altitude up to 4000 m
Sound Pressure * 86 dBA at 100 psi 86 dBA at 0.7 MPa, 7 bar
Sound Power ** 98 dBA at 100 psi 98 dBA at 0.7 MPa, 7 bar
System Weight (empty, no fluid) 2175 lb 987 kg
Air Consumption
Minimum 100 scfm
2.8 meter
3
/min
Maximum 250 scfm
7.1 meter
3
/min
Typical Application 125-175 scfm
3.5-5.0 meter
3
/min
Power Requirements
Voltage (can be set with jumpers) Option 1: 220-240V, 3 phase DELTA (3 wire plus ground)
Option 2: 380-400V, 3 phase WYE (4 wire including neutral
plus ground)
Wattage 18,400 watts (23,400 with optional flush water heater)
Amps 240V, 3-phase models: 65 Amps per phase full load
380V, 3-phase models: 38 Amps per phase full load