User's Manual

Appendix B - Alarms
84 3A2776D
T6F1
T6F2
Tank RTD Failure Advisory Always Temperature sensor is bad Replace temperature sensor
Cable is disconnected or bad Connect temperature sensor cable
to system.
T8DA
T8DB
A/B Material Temperature
Not Rising Alarm
Heater A/B Heater bad. Repair heater.
Heater voltage too low. Increase heater voltage to 200 - 240
VAC.
T8DH Hose Temperature Not Ris-
ing Alarm
Hose
Heater
Heater bad. Repair heater.
Heater voltage too low. Increase heater voltage to 200 - 240
VAC.
V1MA
V1MB
A/B Material Heater Low Line
Voltage Alarm
Always Temperature Control Module power
cable is disconnected.
Plug in module power cable.
Heater circuit breaker is off Turn on heater circuit breaker.
V1MH Hose Heater Low Line Volt-
age Alarm
Always Temperature Control Module power
cable is disconnected.
Plug in module power cable.
Heater circuit breaker is off Turn on heater circuit breaker.
V2MX Voltage Low Control Advisory Always Voltage dropping below 9 Vdc from
power supply.
Change air filter in control filter regu-
lator. See XM PFP repair manual.
Check voltage on information
screen.
V4MA
V4MB
A/B Material Heater High Line
Voltage Alarm
Always Temperature Control Module is bad. Replace module.
Heater is bad. Repair heater.
V4MH Hose Heater High Line Volt-
age Alarm
Always Temperature Control Module is bad. Replace module.
Heater is bad. Repair heater.
Alarm
Code Alarm Problem
When
Active Cause Solution