User's Manual

Appendix A - User Interface Display
3A2776D 65
User Limits Setup Screens
Use these screens to set and adjust pressure and tem-
perature limits for both metering pumps, including limits
that will issue advisories and alarms. Refer to the follow-
ing table for details.
The allowable range for the temperature setpoint is 34° -
160°F (1° - 71°C). If the temperature or pressure set-
point is zero, pressure limits and alarms are disabled.
NOTE: The B metering pump pressure always runs
10-20% higher than the A metering pump pressure.
Process Pressure Limits (for spray mode)
Process Temperature Limits (for spray mode)
Icon Function
Set and adjust pressure limits for both
metering pumps during spray mode.
Set and adjust high and low temperature
limits for both fluid heaters during spray
mode.
Set target pressure or temperature.
Set and adjust limits above or below target
value that if exceeded will issue an advi-
sory. Used with pressure and temperature
limits.
Set and adjust limits above and below tar-
get value that if exceeded will issue a
alarm. Used with pressure and temperature
limits.