User's Manual
Maintenance
3A2776D 53
Clean the System
1. Ensure all equipment is grounded. See Grounding,
page 16.
2. Ensure the area where the sprayer will be cleaned
is well ventilated; and remove all ignition sources.
3. Turn off all heaters and allow equipment to cool.
4. Flush mixed material. See Flush Mixed Material,
page 36.
5. Perform Pressure Relief Procedure, page 38. This
includes flushing the system and parking the meter-
ing pumps.
6. Turn main power switch OFF.
7. Clean external surfaces only using a rag soaked in
solvent that is compatible with the spray material
and the surfaces being cleaned.
8. Allow enough time for solvent to dry before using
sprayer.