User's Manual

System Verification
3A2776D 41
3. Set metering pump air regulator (CD) pressure to
zero. Open metering pump air valve (CA). Adjust
metering pump air regulator (CD) pressure to 50 psi
(0.35 MPa, 3.5 bar).
4. Dispense fluid A:
a. Close recirculation valves, mix manifold inlet
ball valves, and sampling valves.
b. Place a clean 1 quart (1000 cc) container under
sampling valve A.
c. Press . Metering pump A light (DK) comes
on.
d. Slowly open sampling valve A until material
begins to dispense. Metering pump stops auto-
matically; twice during test and again when dis-
pense completes. Metering pump A light (DK)
turns off, metering pump B light (DK) turns on.
e. Close sampling valve A (AE).
5. Dispense fluid B as follows:
a. Place a clean 1 quart (1000 cc) container under
sampling valve B.
b. Slowly open and adjust sampling valve B to
achieve desired flow. Metering pump stops
automatically; twice during test and again when
dispense completes. Metering pump B
light (DK) turns off.
c. Close sampling valve B.
6. Compare fluid amounts in containers; they should
each equal 750 ml (25.3 fl. oz.). Repeat test if fluids
are not equal. If problem persists, see Alarm Code
Troubleshooting, page 79.
7. Return fluid used in test to corresponding fluid sup-
ply container.
Confirm Pump and Metering Test
The Confirm Pump and Metering Test screen displays
when the pump and metering test completes without
error. This screen displays the target weight of material
dispensed into each beaker from each metering pump.
To have your test results entered in the downloadable
USB log files, enter the two weights.
CD
CA
ti20111a
ti20112a