NOTE: If you circulate the A side metering pump above
5200 psi (35.4 MPa, 354 bar), an alarm shuts down the
pump to prevent accidentally spraying material while still
in circulation mode.
18. Once the materials reach the desired temperature
as shown on the supply screen, press .
19. Turn off the main air shutoff valve (CA).
20. Close recirculation valves.
21. Perform Pump and Metering Test on page 40.
22. Perform Ratio Test (Batch Dispense or Ratio
Test) on page 42.
23. Perform Down Stream Valve Leak Test on
page 43.
24. Open mix manifold ball valves.
25. Select .
26. Press to start the metering pumps.
27. Disengage trigger lock and trigger gun into a
grounded metal pail. Use a metal pail lid with a hole
to dispense through to avoid splashing.
28. Adjust metering pump air regulator (CD) to 30 psi
(0.21 MPa, 2.1 bar).
29. Dispense until clean, well-mixed epoxy flows from
the gun.
30. Engage trigger lock.
CA
WLD
ti20128a