User's Manual

Adjust Ratio and System Settings
3A2776D 31
Adjust Ratio and System
Settings
1. Turn key to right (setup position). Yellow LED will
flash and the Setup mode Home screen will display.
2. Press and to change the volume ratio set-
ting.
3. When desired ratio is displayed, turn key to left. Yel-
low LED will turn off.
4. Change all settings in the user-interface to the
desired values. See Appendix A - User Interface
Display on page 58 for detailed screens informa-
tion, including navigation and instructions.
Temperature Settings
Set all temperatures per your materials data sheet spec-
ifications.
Feed Tanks
Temperature is controlled by an adjustable thermostat
on each tank heater. Power to the tank heaters is sup-
plied from the power switches (BB, BC) next to the main
power switch. Tank material temperature is displayed on
the Supply screen under the tank icon. The circulating
heated fluid temperature is displayed on the tempera-
ture gauge next to the heater.
1. Set heater control knob to 4. This is approximately
120°F (49°C).
2. After the red light goes out, check the temperature
on the gauge and adjust as needed to get desired
temperature.
NOTE: Tank will not heat up faster by increasing the
temperature setting.
A and B Material Temperature
There is one Viscon HF 5400 watt heater for heating
material while in circulation or while dispensing. These
heaters are digitally controlled to your specific setpoint
temperature.
The Supply screen controls and displays the setpoint
and actual temperature.
Set the desired A and B temperature. The box next to
the target is the setpoint. The number next to the ther-
mometer is the actual temperature.
Press and to turn on the A and B primary
heaters.
See Spray procedure for pre-heating procedure to use
prior to spraying.
Hose Bundle Temperature
Set the desired hose bundle temperature on the supply
screen.
Be sure the knob on the Viscon HP hose heater (the
middle of the three heaters on the front of the system) is
turned fully clockwise (full ON position). Always leave in
the full ON position. Heater has a separate digital con-
trol module in the junction box.
The heater will heat the water/glycol mixture to 180°F
(82°C) as needed until the hose bundle gets up to the
desired temperature. It will then run at whatever tem-
perature is required to maintain the hose setpoint tem-
perature.
Press to turn the hose bundle heater ON or OFF.