User's Manual
Prime Solvent Flush Pump
3A2776D 29
Prime Solvent Flush Pump
1. Turn main power switch ON and verify the XM PFP
air supply ball valve is open.
2. Fill grounded metal pail with solvent.
3. With the mix manifold inlet ball valves and the mix
manifold solvent flush ball valves closed, trigger the
gun into a grounded pail to remove any residual
pressure.
4. Ensure trigger lock is engaged. Remove spray tip.
5.
If the optional hot water flush kit is not used,
place
solvent flush pump siphon tube in the pail of solvent.
6.
If the optional hot water flush kit is used,
turn on the
water hose connected to the water inlet. Do not turn
on the water heater yet.
7. Open the solvent flush valves.
8. Disengage trigger lock and trigger gun into a
grounded pail. Press gun against the grounded pail.
Use a pail lid with a hole to dispense through. Seal
around hole and gun with a rag to prevent splash
back.
9. Open solvent pump air valve (CB). Pull out and
slowly turn solvent pump air regulator (CG) clock-
wise until solvent pump begins to slowly cycle.
10. Continue to dispense until all air is purged.
11.
If the optional hot water flush kit is used,
perform the
following steps:
• The equipment must be grounded to reduce the
risk of static sparking and electric shock. Hold gun
firmly to side of grounded pail when triggering into
pail.
• Do not point gun at anyone or at any part of the
body.
• Solvent can irritate eyes, nose, throat, and skin.
Hot fluid and parts can burn skin. Wear appropri-
ate protective wear when using flush solvents
and/or if fluid temperature exceeds 110° F (43° C).
• Keep clear of moving parts.
TI19266a
TI19265a2
NOTICE
To avoid burning out the heater element in the
water heater, never turn on the water heater
unless it is filled with water.
ti20110a
CG
CB
TI1953a