8. Open both ball valves on the feed module air con-
trols.
9. If not already set, adjust the feed module settings:
a. Use regulator on the feed module air controls to
set tank air pressure to 60 psi.
b. Adjust silver knob on agitator until it reaches
30 rpm.
c. Adjust silver knob on tank heated fluid circula-
tion pump until it reaches 60 cpm.
d.
If there is no solvent in the tanks,
adjust tank
water heater knob until the 4 is at the 12 o’clock
position then check temperature when the
heater indicator light turns off. Adjust setting
then repeat until desired temperature is
achieved.
10. Open the circulation valves.
11. Verify the sampling valves are closed.
12. Open metering pump inlet ball valves.
13. Turn on air supply and set metering pump air regu-
lator to 20 psi (138 kPa 1.38 bar).
14. At the main run (fluid control) screen, press to
enter manual pump run mode.
15. Press repeatedly to select Metering Pump
A . Press . Slowly turn metering pump air
regulator (CD) clockwise to increase air pressure
until metering pump A starts. Continue to run pump
slowly and dispense into pail until clean material
comes out of the return line. Press to stop
pump. Back out the metering pump air regulator.
F
IG
. 29
To reduce the risk of explosion, never turn on heaters
when solvent is in the system.
FEED PUMP
BYPASS
ti20127a
WLD
NOTICE
Run metering pump as slowly as possible until it is
fully primed to prevent pump damage due to pump
cavitation.