User's Manual

Setup
3A2776D 21
4. Locate the long temperature sensor with black heat
shrink sheath and a connected cable that is
tie-wrapped to the B heater power cable.
a. Cut the temperature sensor loose from the tie
wrap.
b. Insert the sensor down inside the hose bundle
so it is buried in the insulation and up against
the fluid hoses. Be sure the sensor cable will not
get pulled tight by the hose or catch on any-
thing.
c. Use electrical tape to wrap the hose bundle
from where it connects to the system to the
hose sheath. This insulates and protects the
hose bundle.
Connect the Fluid Hose Bundle
to the Mix Manifold
1. Unroll the hose bundle out to the spray area.
2. Model 262869: Connect the 3/4 in. A and 1/2 in. B
hoses to the material inlet ball valves on the mix
manifold. See F
IG
. 20.
Model 24W626: Connect the 3/4 in. A and 3/4 in. B
hoses to the material inlet ball valves on the mix
manifold. Color code material hoses (green and
blue) with respective color identification on mix
manifold. See F
IG
. 20.
3. Remove the U-shaped tube connectors only from
the end of the longer set of red and blue tubes. Trim
the excess tubing to fit the one set of the red and
blue tubes fully into the two brass compression fit-
tings on the aluminum heat circulation plate under
the main manifold. Tighten the compression fittings.
4. Route the purple solvent flush hoses from the mani-
fold underneath the manifold carriage and connect
to the 1/4 in. flush hose in the hose bundle.
See F
IG
. 20.
5. Use electrical tape to wrap the hose bundle from
where it connects to the system to the hose sheath.
This insulates and protects the hose bundle.
F
IG
. 19
ti20274a
F
IG
. 20
Material Inlets
Solvent Inlet
ti20088a