User's Manual
Technical Data
Technical Data
US
Metric
Maximum Pressures:
Maximum inlet air pressure I/P transducer 130 psig 10.3 bar
Maximum fluid working pressure
289813 G300
0 Meter
4000 psi 28 MPa, 276 bar
24C375 Fluid Regulator
100 psi 0.7 MPa, 7 bar
Maximum fluid inlet pressure
24C375 Fl
uid Regulator
300psi 2.1MPa,21bar
Power In Requirements:
Voltage:
90–264 V
AC
Frequency: 50-60 Hz
Phase: 1
Amps: 1.25A m
aximum
Power Out Requirements:
Power Supply 16V680 15 VDC, 1.2 A maximum
Powe
r Supply 16M167
15 VD
C, 160mA maximum
Environmental
Ope
rating Temperature
32°
-122°F
0°-
50°C
Storage Temperature –22°-140°F –30°-60°C
Hu
midity
0t
o 95 percent, non-condensing
Display housing is solvent resistant.
Wetted Parts
M
eter
See G3000 meter manual (308778) or Coriolis
meter manual (313599)
Fluid Regulator
See Fluid Regulator Manual (3A0427)
Fittings
Stainless Steel
Weight
ProControl 1KE
1.5 lb 0.68 kg
Mounting Bracket 1 lb 0.45 kg
Power Supply 16M167
9lb 4.1kg
Fluid Plate (fully populated)
10.5 lb 4.76 kg
3A2614F 53