User's Manual

Appendix B - Adva
nced Web Interface
Target
In this screen
section, view or adjust your
maintenance t
arget, the upper and lower limits
foroperatora
djustment of flow rate percent, and
maximum and mi
nimum flow rate values. Type the
desired numb
er in the field. Changes made to the
upper and low
er flow rate targets will take effect the
next time the
operator enters a new flow rate on the
ProControl 1
KE Module.
Units
In this screen section, view or adjust the desired
units for pressure, flow rate, batch total, and grand
total. Also enable or disable the pressure sensor
and flow meter. Use the dropdown menu for each to
select different units, or to toggle between Enable
and Disable, if desired.
K-Factor
In this screen section, view or adjust the k-factor for
the system’s meter. See Calibrate the Meter, page 18.
Device Name
In this screen
section, type a name in the field to help
you different
iate among ProControl1KEs, if you are
using more tha
n one.
Events
In this screen section, view or adjust the alarm
settings and backlight timer. Use the dropdown
menus to toggle between On and Off for the
maintenance alarm, flow alarm, and auto clear. For
the backlight timer, type a number in the field to
correspond to the number of minutes the display can
be idle before it turns off the backlight to save power.
Modbus
In thi
s screen section, view the modbus mode,
addre
ss, baud rate, and parity. Modbus information
must b
e adjusted on the ProControl 1KE. If you were
to adj
ust it on your PC, the change would cause a
disru
ption in your connection.
3A2614F 51