User's Manual
Appendix A - Modb
us Variable Map
Register
Permis-
sions
Informer
Modbus
Register
Description
Size
Units Low
Limit
High
Limit
Notes
Read/Write 403019
System, Fluid
Flow Percent
Maximum Set Po
int
16 Bit
percent
0 999 0 to 99.9
percent
Read/Write 403020
System, Flow Percent Minimum
Set Point
16 Bit
percent
0 999 0 to 99.9
percent
Read/Write 403021
System, Flow Rate Maximum
32 Bit
cc
0 999000
Read/Write 403023
System, Flow Rate Minimum
32 Bit
cc
0 999000
Read/Write 403025
System, Meter K-Factor
16 Bit
cc
10 5000 0.010 to
5.000 cc
Read/Write 403026
System, Pressure Transducer
Type
16 Bit 0=Type 1,
1=Type 2
0 1 Type 1. 100
psi
Type 2. 7500
psi
Read/Write 403027
System, Pressure Transducer
Offset
32 Bit mV 0 999999 0 to 9999.99
mV
Read/Write 403029
System,
Pressure Transducer
Scale
32 Bit mV/Bar 0 999999 0 to 9.99999
mV/Bar
3A2614F