User's Manual

Appendix A - Modb
us Variable Map
Register
Permissions
Informer
Modbus
Register
Description
Size
Units Low
Limit
High Limit Notes
Read Only
402014
Current Flow R
ate
32 Bit cc/min 0 65536
Read Only
402016
Current Press
ure
32 Bit bar 0 65536 x 1000
Read 402018
Current Pres
sure Target
16 Bit
percent
0999 0to99.9
percent
Read/Write 402019
Calibration
Mode
16 Bit
0-off, 1=on
01
Read/Write 402020
Calibratio
n, Measured Volume
32 Bit pulses 0 32-bit
Read/Write 402022
Calibratio
n, Actual Dispensed
Volume
32 Bit
cc
0 32-bit
Table 13 Setup Registers
Register
Permis-
sions
Informer
Modbus
Register
Descripti
on
Size
Units Low
Limit
High
Limit
Notes
Read/Write 403000
Communication, Modbus Mode
16 Bit
0=off, 1=on
01
Read/Write 403001
Communication, Modbus Address
32 Bit 1-247 1 247
Read/Write 403003
Communication, Modbus Baud
Rate
16 Bit 0=9600,
1=19200,
2=38400,
3=578600,
4=115200
04
Read/Write 403004
Communication, Modbus Parity
16 Bit 0=None,
1=Odd,
2=Even
02
Read/Write 403005
Communication, Modbus
StopBits
16 Bit
none
12
Read/Write 403006 Display, Date Format 16 Bit 0=mm/dd/yy,
1=dd/mm/yy,
2=yy/mm/dd
02
Read/Write 403007 Display, Backlight Timer 16 Bit min 0 99
Read/Write 403008 Display, Maintenance Totalizer
Alarm Enable
16 Bit
0=of
f, 1=on
01
Read/Write 403009 Display, Flow Rate Alarm Enable 16 Bit
0=o
ff, 1=on
01
Read/Write 403010
Dis
play, Alarm Auto Clear
16 Bit
0=o
ff, 1=on
01
Read/Write 403011 Flow Meter Enable 16 Bit
0=o
ff, 1=on
01
Read/Write 403012 Pressure Transducer Enable 16 bit
0=o
ff, 1=on
01
Read/Write 403013 Units, Flow Rate 16 Bit 0=cc/min,
1=l/min,
2=gal/min
02
Read/write 403014 Units, Pressure 16 Bit 0=psi, 1=bar,
2=MPa
02
Read/Write 403015 Units, Batch Volume 16 Bit 0=cc, 1=l,
2=gal
02
(/1000)
Read/Write 403016
U
nits, Grand Volume
16 Bit 0=cc, 1=l,
2=gal
02
Read/Write 403017
System, Maintenance Target
32 Bit
cc
0 999999
46 3A2614F