User's Manual
Setup Screens
Setup Screen 2
Use this screen to set the upper and lower limits for
operator adjustment of flow rate percent and to select
your preferred pressure units.
Key
Enter the screen to set or change
preferences.
Press to activate a field for editing or to
accept the highlighted selection on a
dropdown menu.
Move to t
he right when editing number
fields.
Press again to accept the entry
when al
l digits are correct.
Set you
r desired upper (first data field)
and lo
wer (second data field) fluid flow
perce
nt set limits. The Operator can
adjus
t the percentage on Run Screen 1
only w
ithin these limits.
Pres
sure units — select from the
foll
owingdropdownoptions.
Select if system has no pressure
transducer.
Ex
it data editing.
Move between Setup Screens, fields on
a screen, or to increment/decrement the
digits when editing number fields.
SetupScreen3
Use this screen to set your flow rate maximum and
minimum values and to select your preferred flow
rate units.
Key
Enter the screen to set or change
preferences.
Presstoactivateafieldforeditingorto
accept the highlighted selection on a
dropdown menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Set your desired maximum (first data
field) and minimum (second data field)
flow rates. Flow rates outside of these
parameters will trigger an alarm. See
Setup Screen 4, page 28, to set or
disable the flow rate alarms.
Flow Rate Units - Select from the
following drop down options.
Select if system has no flow
meter.
Exit data editing.
Move between Setup Screens, fields on
a screen, or to increment/decrement the
digits when editing number fields.
3A2614F
27