User's Manual
Troubleshooting
Problem Problem
Problem
Cause Cause
Cause
Solution Solution
Solution
Operatornotgroundedorisnear
ungroundedobject.
SeeGrounding,page26.
Gunnotgrounded.SeeCheckGunElectrical
Grounding,page28,and
TestGunResistance,page39.
Operatorgetsmildshock.
Aweakstaticchargehasbuiltup
onthesurfaceofanunshielded
uidhose.Thisisachargeonthe
hosesurface,notafailureofthe
hoseinsulation.
Bundleandwraptheairanduid
hosestogether.SeeConnectthe
WaterborneFluidHose,page18.
Operatorgetsshockfrom
workpiece.
Workpiecenotgrounded.Resistancemustbe1megohmor
less.Cleanworkpiecehangers.
Gunistooclosetothepartbeing
sprayed.
Gunshouldbe8–12in.(200–300
mm)fromthepart.
Voltage/currentdisplaystaysred
(smartgunsonly).
Dirtygun.
SeeCleantheGunDaily,page37.
ESorHzindicatorisamber.
Alternatorspeedistoolow.Increaseairpressureuntil
indicatorisgreen.Toavoid
over-atomization,usethe
atomizingairrestrictorvalveto
reducetheatomizingairtotheair
cap.
ESorHzindicatorisred.
Alternatorspeedistoohigh.Decreaseairpressureuntil
indicatorisgreen.
ErrordisplayappearsandHz
indicatorisred(Smartgunsonly).
Smartmodulehaslost
communicationwiththepower
supply.
Checkforgoodconnectionsbe-
tweentheSmartModuleandthe
powersupply.SeeSmartModule
Replacement,page66and
PowerSupplyRemovaland
Replacement,page59.
3A2496D 49