User's Manual
Operation
11.Sprayatestpattern.Checktheatomization.If
over-atomizationoccursatminimumpressure,
adjusttherestrictorvalve.Ifatomizationis
inadequate,increaseairpressureordecrease
uidow.
12.Adjustthefanairadjustmentvalve:clockwisefor
anarrowerpattern,counterclockwiseforawider
pattern.
WhentheESOn-OffswitchisturnedON(I),
theuidsupplyischargedwithhighvoltage
untilthevoltageisdischarged.Contactwith
thechargedcomponentsofthespraygunwill
causeanelectricshock.Donottouchthegun
nozzleorelectrodeorcomewithin4in.(102
mm)ofthefrontofthegunduringoperation.
13.TurnON(I)theESOn-Offswitch(J).
14.CheckthattheESindicator(Hzindicatoron
Smartguns)islit,orcheckthatthekVindicator
ontheisolatedenclosurereads45–55kV.See
thefollowingtable.
Table Table
Table
3 3
3
. .
.
LED LED
LED
Indicator Indicator
Indicator
Colors Colors
Colors
Indicator Indicator
Indicator
Color Color
Color
Description Description
Description
Green
Whenspraying,the
indicatorshould
remaingreen,
indicatingsufcient
airpressuretothe
alternatorturbine.
Amber
Iftheindicatorturns
amberafter1sec,the
airpressureistoolow.
Increaseairpressure
untiltheindicatoris
green.
Red
Iftheindicatorturns
redafter1sec,theair
pressureistoohigh.
Decreaseairpressure
untiltheindicatoris
green.
15.CheckthekVmeterontheisolatedenclosure;
45–55kVisnormal.
16.Sprayatestpiece.Examinetheedges
forcoverage.Ifwrapispoor,see
SprayPatternTroubleshooting,page46.
17.Whenyounishspraying,perform
Shutdown,page35.
34 3A2496D