User's Manual

GunOverview
Smart Smart
Smart
Guns Guns
Guns
TheSmartGunmoduledisplayssprayingvoltage,
current,alternatorspeed,andthevoltagesetting(low
orhigh).Italsoallowstheusertochangetoalower
sprayingvoltage.Themodulehastwomodes:
OperatingMode
DiagnosticMode
Operating Operating
Operating
Mode Mode
Mode
Bar Bar
Bar
Graph Graph
Graph
SeeFig.2,andTable1onpage12.TheOperating
Modedisplaysgundataduringnormalspraying.The
displayusesabargraphtoshowthevoltagelevelin
kiloVolts(kV)andthecurrentlevelinmicroAmperes
(uA).Thebargraphrangeisfrom0to100%foreach
value.
IfthebargraphLEDsareblue,thegunisreadyto
spray.IftheLEDsareyelloworred,thecurrentis
toohigh.Theuidmaybetooconductive,orsee
ElectricalTroubleshooting,page48forotherpossible
causes.
Hz Hz
Hz
Indicator Indicator
Indicator
TheHzindicatorfunctionsthesameastheES
indicatoronstandardguns.Theindicatorlightsto
showthealternatorspeedstatus,andhasthree
colors:
Greenindicatesthealternatorspeediscorrect.
Iftheindicatorchangestoamberafter1second,
increasetheairpressure.
Iftheindicatorchangestoredafter1second,
reducetheairpressure.
Voltage Voltage
Voltage
Adjustment Adjustment
Adjustment
Switch Switch
Switch
Thevoltageadjustmentswitch(VA)allowsthe
operatortochangefromlowtohighvoltage.
Thehighvoltagesettingisdeterminedbythe
maximumvoltageofthegunandisnotadjustable.
Thelowvoltageindicator(LO)lights
whentheswitchissettoLO.Thelow
voltagesettingisuseradjustable.See
AdjustingtheLowVoltageSetting,page11.
NOTE: NOTE:
NOTE:
IftheErrordisplayappears,theSmartmodule
haslostcommunicationwiththepowersupply.See
ErrorDisplay,page11forfurtherinformation.
Figure2SmartGunModuleinOperatingMode
10 3A2496D